<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.monvisoenergia.it/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Andrea+C</id>
	<title>Smart Biogas Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.monvisoenergia.it/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Andrea+C"/>
	<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php/Special:Contributions/Andrea_C"/>
	<updated>2026-11-16T19:36:24Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.44.2</generator>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Filiera&amp;diff=267</id>
		<title>Plant/Filiera</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Filiera&amp;diff=267"/>
		<updated>2026-05-25T13:57:37Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Selezionare la filiera energetica.&lt;br /&gt;
&lt;br /&gt;
La Direttiva RED2 ed il D.Lgs. 199/2022 ammettono le seguenti produzioni:&lt;br /&gt;
&lt;br /&gt;
*BGE: cogenerazione di energia elettrica e termica (biogas elettrico)&lt;br /&gt;
*BGH: calore o raffrescamento&lt;br /&gt;
*BGT: Biometano per uso autotrasporti&lt;br /&gt;
*BGA: Biometano per altri usi (energia elettrica, calore e raffrescamento)&lt;br /&gt;
&lt;br /&gt;
In base all&#039;uso finale del prodotto energetico viene effettuato il calcolo di sostenibilità impiegando le relative formula fornite dalla RED2 e dal D.Lgs. 199/2022&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Potenza_elettrica_massima_in_immissione_(connessione)&amp;diff=266</id>
		<title>Plant/Potenza elettrica massima in immissione (connessione)</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Potenza_elettrica_massima_in_immissione_(connessione)&amp;diff=266"/>
		<updated>2026-05-25T13:56:18Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;E&amp;#039; la potenza massima di immissione come risultante dalla documentazione del gestore e su TERNA Gaudì&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;E&#039; la potenza massima di immissione come risultante dalla documentazione del gestore e su TERNA Gaudì&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Configurazione&amp;diff=265</id>
		<title>Plant/Configurazione</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Configurazione&amp;diff=265"/>
		<updated>2026-05-25T13:55:31Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;E&amp;#039; la configurazione elettrica presente in impianto come risultante dalla documentazione enel ed eventualmente comunicata al GSE:  * Cessione totale: tutta l&amp;#039;elettricità è immessa in rete e nulla è consumato da utenze aziendali diverse dai servizi ausiliari * Cessione parziale: l&amp;#039;elettricità viene parzialmente consumata in azienda da utenze diverse dagli ausiliari di impianto (es. utenze agricole)&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;E&#039; la configurazione elettrica presente in impianto come risultante dalla documentazione enel ed eventualmente comunicata al GSE:&lt;br /&gt;
&lt;br /&gt;
* Cessione totale: tutta l&#039;elettricità è immessa in rete e nulla è consumato da utenze aziendali diverse dai servizi ausiliari&lt;br /&gt;
* Cessione parziale: l&#039;elettricità viene parzialmente consumata in azienda da utenze diverse dagli ausiliari di impianto (es. utenze agricole)&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Asservito_a_processi&amp;diff=264</id>
		<title>Plant/Asservito a processi</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Asservito_a_processi&amp;diff=264"/>
		<updated>2026-05-25T13:53:03Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Indicare se l&#039;impianto è asservito ad un processo produttivo interno o esterno all&#039;azienda al sensi della Delibera ARERA 174/2026.&lt;br /&gt;
&lt;br /&gt;
L&#039;asservimento può essere:&lt;br /&gt;
&lt;br /&gt;
* Solo elettricità ceduta all&#039;utenza&lt;br /&gt;
* Solo calore ceduto all&#039;utenza&lt;br /&gt;
* Calore ed elettriciità&lt;br /&gt;
Selezionare l&#039;opzione in base alle informazioni tecniche ed agli eventuali contatori di energia presenti in impianto&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Asservito_a_processi&amp;diff=261</id>
		<title>Plant/Asservito a processi</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Asservito_a_processi&amp;diff=261"/>
		<updated>2026-05-25T11:01:51Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Indicare se l&#039;impianto è asservito ad un processo produttivo interno o esterno all&#039;azienda al sensi della Delibera ARERA 174/2026.&lt;br /&gt;
&lt;br /&gt;
L&#039;asservimento può essere:&lt;br /&gt;
&lt;br /&gt;
* solo elettricità ceduta all&#039;utenza&lt;br /&gt;
* Solo calore ceduto all&#039;utenbza&lt;br /&gt;
* Calore ed elettriciità&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Asservito_a_processi&amp;diff=260</id>
		<title>Plant/Asservito a processi</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Asservito_a_processi&amp;diff=260"/>
		<updated>2026-05-25T10:57:58Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: creato&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Indicare se l&#039;impianto è asservito ad un processo produttivo interno o esterno all&#039;azienda al sensi della Delibera ARERA 174/2026.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Stoccaggio_digestato_tal_quale&amp;diff=94</id>
		<title>Plant/Stoccaggio digestato tal quale</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Stoccaggio_digestato_tal_quale&amp;diff=94"/>
		<updated>2025-07-30T15:16:30Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;Il DM biometano impone di disporre di vasca coperta del digestato da 30 gg di ritenzione, con recupero del gas ed uso energetico. Il biogas elettrici non ha previsioni di alcun tipo, ma gli impianti soggetti a sostenibilità debbono gestire il digestato in modo tale da rispettare il vincolo di riduzione delle emissioni delll&amp;#039;80% rispetto a FFC.  Quindi si possono avere due casi: 1) Digestato tal quale coperto almeno a 30 gg con recupero gas in questo caso non è rilevant...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Il DM biometano impone di disporre di vasca coperta del digestato da 30 gg di ritenzione, con recupero del gas ed uso energetico.&lt;br /&gt;
Il biogas elettrici non ha previsioni di alcun tipo, ma gli impianti soggetti a sostenibilità debbono gestire il digestato in modo tale da rispettare il vincolo di riduzione delle emissioni delll&#039;80% rispetto a FFC.&lt;br /&gt;
&lt;br /&gt;
Quindi si possono avere due casi:&lt;br /&gt;
1) Digestato tal quale coperto almeno a 30 gg con recupero gas&lt;br /&gt;
in questo caso non è rilevante la successiva gestione del digestato eventualmente separato in frazione solida e liquida.&lt;br /&gt;
&lt;br /&gt;
2) Digestato immediatamente separato:&lt;br /&gt;
In questo caso è rilevante capire se la frazione liquida e solida sono coperte almeno 30 gg con recupero gas. In questo caso il digestato è ancora considerato coperto.&lt;br /&gt;
Se solo il liquido è coperto a recupero per almeno 30 gg ed il solido scoperto si può applicare la correzione prevista dalla Norma UNITS 11567:2024&lt;br /&gt;
Se entrambi sono scoperti o coperti senza recupero allora la configurazione da usare è quella di digestato aperto.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Oxidation_catalyst&amp;diff=93</id>
		<title>Plant/Oxidation catalyst</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Oxidation_catalyst&amp;diff=93"/>
		<updated>2025-06-23T16:57:33Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;I catalizzatori ossidativi nel biogas sono utilizzati per ridurre le emissioni inquinanti, come il monossido di carbonio (CO), gli idrocarburi (HC) e la formaldeide, trasformandoli in sostanze innocue come anidride carbonica (CO2) e acqua (H2O). Questi catalizzatori sono importanti per soddisfare gli standard di emissione nei sistemi di cogenerazione che utilizzano biogas. La porzione catalitica del sistema va sostituita periodicamente per mantenere gli abbattimenti prev...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;I catalizzatori ossidativi nel biogas sono utilizzati per ridurre le emissioni inquinanti, come il monossido di carbonio (CO), gli idrocarburi (HC) e la formaldeide, trasformandoli in sostanze innocue come anidride carbonica (CO2) e acqua (H2O). Questi catalizzatori sono importanti per soddisfare gli standard di emissione nei sistemi di cogenerazione che utilizzano biogas. La porzione catalitica del sistema va sostituita periodicamente per mantenere gli abbattimenti previsti.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Actually_used_recovered_heath&amp;diff=92</id>
		<title>Plant/Actually used recovered heath</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Actually_used_recovered_heath&amp;diff=92"/>
		<updated>2025-06-17T10:49:27Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;This is the actually recovered heat. Consider only the heat used in process other than the ones for the biogas/biomethane production. Ex. external uses for heating in households.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;This is the actually recovered heat. Consider only the heat used in process other than the ones for the biogas/biomethane production. Ex. external uses for heating in households.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/RTO&amp;diff=91</id>
		<title>Plant/RTO</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/RTO&amp;diff=91"/>
		<updated>2025-05-09T11:55:38Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;In a Rigenerative Thermal Oxidation system instaleld on the exaust line of the CHP? Ita can contribute to significantly reduce the CH4 concentration in the exaust.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;In a Rigenerative Thermal Oxidation system instaleld on the exaust line of the CHP? Ita can contribute to significantly reduce the CH4 concentration in the exaust.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Control_Points/Frequenza_di_reset_della_misura_(unit%C3%A0)&amp;diff=83</id>
		<title>Control Points/Frequenza di reset della misura (unità)</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Control_Points/Frequenza_di_reset_della_misura_(unit%C3%A0)&amp;diff=83"/>
		<updated>2025-01-02T15:41:12Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;Molti strumenti di misura (es. contatori dell&amp;#039;energia elettrica) o diversi sistemi di gestione tramite PLC hanno un reset periodico delle letture, esempio mensile o annuale. In questo caso ad ogni inizio mese o anno la lettura riparte da zero. L&amp;#039;unità di frequenza di reset rappresenta l&amp;#039;unità di tempo con quale si desidera gestire il reset delle letture.  Se si inserisce mese il sistema si attende poi di sapere ogni quanti kesi avviene il reset della lettura (tipicamen...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Molti strumenti di misura (es. contatori dell&#039;energia elettrica) o diversi sistemi di gestione tramite PLC hanno un reset periodico delle letture, esempio mensile o annuale. In questo caso ad ogni inizio mese o anno la lettura riparte da zero.&lt;br /&gt;
L&#039;unità di frequenza di reset rappresenta l&#039;unità di tempo con quale si desidera gestire il reset delle letture. &lt;br /&gt;
Se si inserisce mese il sistema si attende poi di sapere ogni quanti kesi avviene il reset della lettura (tipicamente uno).&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Stoccaggio_coperto_30gg&amp;diff=73</id>
		<title>Plant/Stoccaggio coperto 30gg</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Stoccaggio_coperto_30gg&amp;diff=73"/>
		<updated>2023-05-13T09:17:40Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Digestato stoccato in strutture coperte con contemporaneo recupero di biogas per fini energetici per un periodo definito. &lt;br /&gt;
&lt;br /&gt;
Tale periodo è pari a 30 giorni nel caso di successivo utilizzo agronomico o pari a 60 giorni nel caso di digestione anaerobica dei fanghi.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Filiera&amp;diff=72</id>
		<title>Plant/Filiera</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Filiera&amp;diff=72"/>
		<updated>2023-05-13T09:14:36Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: aggiunto definizione&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Selezionare la filiera energetica.&lt;br /&gt;
&lt;br /&gt;
La Direttiva RED2 ed il D.Lgs. 199/2022 ammettono le seguenti produzioni:&lt;br /&gt;
&lt;br /&gt;
*cogenerazione di energia elettrica e termica&lt;br /&gt;
*calore o raffrescamento&lt;br /&gt;
*Biometano per uso autotrasporti&lt;br /&gt;
*Biometano per altri usi (energia elettrica, calore e raffrescamento)&lt;br /&gt;
&lt;br /&gt;
In base all&#039;uso finale del prodotto energetico viene effettuato il calcolo di sostenibilità impiegando le relative formula fornite dalla RED2 e dal D.Lgs. 199/2022&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Temperatura_calore&amp;diff=46</id>
		<title>Plant/Temperatura calore</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Temperatura_calore&amp;diff=46"/>
		<updated>2022-11-26T11:10:01Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Nel sistema la temperatura è espressa in °C per comodità e poi convertita in K.&lt;br /&gt;
&lt;br /&gt;
Secondo RED2: &#039;&#039;Th =la temperatura, misurata in temperatura assoluta (kelvin) del calore utile al punto di fornitura. T0 =la temperatura ambiente, fissata a 273,15 kelvin (pari a 0 °C).&#039;&#039;&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Temperatura_calore&amp;diff=45</id>
		<title>Plant/Temperatura calore</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Temperatura_calore&amp;diff=45"/>
		<updated>2022-11-26T11:09:40Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;Nel sistema la temperatura è espressa in °C per comodità e poi convertita in K. Secondo RED2: Th =la temperatura, misurata in temperatura assoluta (kelvin) del calore utile al punto di fornitura. T0 =la temperatura ambiente, fissata a 273,15 kelvin (pari a 0 °C).&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Nel sistema la temperatura è espressa in °C per comodità e poi convertita in K.&lt;br /&gt;
Secondo RED2: Th =la temperatura, misurata in temperatura assoluta (kelvin) del calore utile al punto di fornitura. T0 =la temperatura ambiente, fissata a 273,15 kelvin (pari a 0 °C).&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_termica_uso_finale&amp;diff=44</id>
		<title>Plant/Efficienza termica uso finale</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_termica_uso_finale&amp;diff=44"/>
		<updated>2022-11-26T11:07:52Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;E&#039; il rapporto fra il calore utile prodotto e l&#039;energia contenuta nel biogas/biometano avviato all&#039;utilizzo nella macchina per il prodotto energetico finale. Es. per il biogas elettrico è il calore utile (effettivamente utilizzato per fini commerciali, residenziali, industriali, ecc) fratto il potere calorico del biogas per il flusso di biogas nell&#039;unità di tempo (in questo caso l&#039;anno). Per il biometano è l&#039;energia termica netta prodotta dal generatore per gli usi finali (es. CHP industriale) effettivamente impiegata nel processo industriale ed il contenuto energetico del biometano impiegato nell&#039;unità di tempo.&lt;br /&gt;
&lt;br /&gt;
Secondo la RED2 &amp;quot;&#039;&#039;ηh =l&#039;efficienza termica, definita come l&#039;energia termica prodotta annualmente divisa per l&#039;input annuale di combustibile, in base al suo contenuto energetico&#039;&#039;&amp;quot;.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_elettrica_uso_finale&amp;diff=43</id>
		<title>Plant/Efficienza elettrica uso finale</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_elettrica_uso_finale&amp;diff=43"/>
		<updated>2022-11-26T11:06:02Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;E&#039; il rapporto fra l&#039;elettricità utile prodotta e l&#039;energia contenuta nel biogas/biometano avviato all&#039;utilizzo nella macchina per il prodotto energetico finale. Es. per il biogas elettrico è l&#039;elettricità netta immessa in rete (quindi al netto dei consumi dei servizi ausiliari del CHP e dell&#039;impianto di digestione) fratto il potere calorico del biogas per il flusso di biogas nell&#039;unità di tempo (in questo caso l&#039;anno). Non è quindi il rendimento elettrico del motore ma l&#039;efficienza netta del processo di produzione di energia elettrica in riferimento al biogas captato e quindi energia elettrica netta immessa su contenuto energetico del biogas inviato al CHP nell&#039;unità di tempo.&lt;br /&gt;
&lt;br /&gt;
Per il biometano è l&#039;energia elettrica netta prodotta dal generatore per gli usi finali (es. CHP industriale) ed il contenuto energetico del biometano impiegato nell&#039;unità di tempo.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_termica_uso_finale&amp;diff=42</id>
		<title>Plant/Efficienza termica uso finale</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_termica_uso_finale&amp;diff=42"/>
		<updated>2022-11-26T11:03:52Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;E&amp;#039; il rapporto fra il calore utile prodotto e l&amp;#039;energia contenuta nel biogas/biometano avviato all&amp;#039;utilizzo nella macchina per il prodotto energetico finale. Es. per il biogas elettrico è il calore utile (effettivamente utilizzato per fini commerciali, residenziali, industriali, ecc) fratto il potere calorico del biogas per il flusso di biogas nell&amp;#039;unità di tempo (in questo caso l&amp;#039;anno). Per il biometano è l&amp;#039;energia termica netta prodotta dal generatore per gli usi fi...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;E&#039; il rapporto fra il calore utile prodotto e l&#039;energia contenuta nel biogas/biometano avviato all&#039;utilizzo nella macchina per il prodotto energetico finale. Es. per il biogas elettrico è il calore utile (effettivamente utilizzato per fini commerciali, residenziali, industriali, ecc) fratto il potere calorico del biogas per il flusso di biogas nell&#039;unità di tempo (in questo caso l&#039;anno). Per il biometano è l&#039;energia termica netta prodotta dal generatore per gli usi finali (es. CHP industriale) effettivamente impiegata nel processo industriale ed il contenuto energetico del biometano impiegato nell&#039;unità di tempo.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_elettrica_uso_finale&amp;diff=41</id>
		<title>Plant/Efficienza elettrica uso finale</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Efficienza_elettrica_uso_finale&amp;diff=41"/>
		<updated>2022-11-26T11:00:36Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;E&amp;#039; il rapporto fra l&amp;#039;elettricità utile prodotta e l&amp;#039;energia contenuta nel biogas/biometano avviato all&amp;#039;utilizzo nella macchina per il prodotto energetico finale. Es. per il biogas elettrico è l&amp;#039;elettricità netta immessa in rete fratto il potere calorico del biogas per il flusso di biogas nell&amp;#039;unità di tempo (in questo caso l&amp;#039;anno). Per il biometano è l&amp;#039;energia elettrica netta prodotta dal generatore per gli usi finali (es. CHP industriale) ed il contenuto energetico...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;E&#039; il rapporto fra l&#039;elettricità utile prodotta e l&#039;energia contenuta nel biogas/biometano avviato all&#039;utilizzo nella macchina per il prodotto energetico finale. Es. per il biogas elettrico è l&#039;elettricità netta immessa in rete fratto il potere calorico del biogas per il flusso di biogas nell&#039;unità di tempo (in questo caso l&#039;anno). Per il biometano è l&#039;energia elettrica netta prodotta dal generatore per gli usi finali (es. CHP industriale) ed il contenuto energetico del biometano impiegato nell&#039;unità di tempo.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Perdite_Biogas_nel_processo&amp;diff=40</id>
		<title>Plant/Perdite Biogas nel processo</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Perdite_Biogas_nel_processo&amp;diff=40"/>
		<updated>2022-11-26T10:57:15Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;Sono le perdite complessive di biogas nel processo di digestione a monte della captazione ed invio al CHP o al sistema di upgrading. Tipicamente sono le perdite da gasometri danneggiati, guardie idrauliche, tubazioni e giunti ecc. Ad oggi la RED2 non tiene conto di tali perdite che sono comunque presenti.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Sono le perdite complessive di biogas nel processo di digestione a monte della captazione ed invio al CHP o al sistema di upgrading. Tipicamente sono le perdite da gasometri danneggiati, guardie idrauliche, tubazioni e giunti ecc. Ad oggi la RED2 non tiene conto di tali perdite che sono comunque presenti.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Perdite_CH4_off_gas&amp;diff=39</id>
		<title>Plant/Perdite CH4 off gas</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Perdite_CH4_off_gas&amp;diff=39"/>
		<updated>2022-11-26T10:55:42Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;Le perdite di metano nell&amp;#039;off gas sono calcolate in rapporto al flusso di metano in entrata all&amp;#039;upgrading. Quindi so il complementare al rapporto fra metano nel biometano ed il metano nel biogas in ingresso all&amp;#039;impianto di upgrading.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Le perdite di metano nell&#039;off gas sono calcolate in rapporto al flusso di metano in entrata all&#039;upgrading. Quindi so il complementare al rapporto fra metano nel biometano ed il metano nel biogas in ingresso all&#039;impianto di upgrading.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Stoccaggio_coperto_30gg&amp;diff=38</id>
		<title>Plant/Stoccaggio coperto 30gg</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Stoccaggio_coperto_30gg&amp;diff=38"/>
		<updated>2022-11-26T10:54:05Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;Digestato stoccato in strutture coperte con contemporaneo recupero di biogas per un periodo definito. Tale periodo è pari a 30 giorni nel caso di successivo utilizzo agronomico o pari a 60 giorni nel caso di digestione anaerobica dei fanghi .&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Digestato stoccato in strutture coperte con contemporaneo recupero di biogas per un periodo definito. Tale periodo è pari a 30 giorni nel caso di successivo utilizzo agronomico o pari a 60 giorni nel caso di digestione anaerobica dei fanghi .&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Final_use_thermal_efficiency&amp;diff=37</id>
		<title>Plant/Final use thermal efficiency</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Final_use_thermal_efficiency&amp;diff=37"/>
		<updated>2022-10-16T17:11:30Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;The final use heat efficiency is the amount of heat that can be practically recovered from the CHP and really exploited  compared to the energy content of the biomethane used in the CHP or in the gas boiler.  According to RED2, &amp;quot;The heat efficiency, defined as the annual useful heat output divided by the annual energy input, based on its energy content&amp;quot;.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The final use heat efficiency is the amount of heat that can be practically recovered from the CHP and really exploited  compared to the energy content of the biomethane used in the CHP or in the gas boiler. &lt;br /&gt;
According to RED2, &amp;quot;The heat efficiency, defined as the annual useful heat output divided by the annual energy input, based on its energy content&amp;quot;.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Final_use_electrical_efficiency&amp;diff=36</id>
		<title>Plant/Final use electrical efficiency</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Final_use_electrical_efficiency&amp;diff=36"/>
		<updated>2022-10-16T17:06:15Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;The final use electrical efficiency is the exploited electricity generated from the biomethane compared to the biomethane energy content. It can be calculated with the CHP efficiency considering also the CHP consumption. In a sample case where biomethane is used by a CHP system with an elecrical efficiency of 40% and that use 3% of the generated electricity for the CHP services (cooling, software, lights, etc), the efficiency to be considered is 40 x 0,97 = 38,8%.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;The final use electrical efficiency is the exploited electricity generated from the biomethane compared to the biomethane energy content. It can be calculated with the CHP efficiency considering also the CHP consumption. In a sample case where biomethane is used by a CHP system with an elecrical efficiency of 40% and that use 3% of the generated electricity for the CHP services (cooling, software, lights, etc), the efficiency to be considered is 40 x 0,97 = 38,8%.&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
	<entry>
		<id>https://wiki.monvisoenergia.it/index.php?title=Plant/Electricity_for_the_process&amp;diff=35</id>
		<title>Plant/Electricity for the process</title>
		<link rel="alternate" type="text/html" href="https://wiki.monvisoenergia.it/index.php?title=Plant/Electricity_for_the_process&amp;diff=35"/>
		<updated>2022-10-16T17:00:52Z</updated>

		<summary type="html">&lt;p&gt;Andrea C: Created page with &amp;quot;In this field should be indicated the source of the electricity used in the process (mixers, feeders, etc). The source can be the nationl grid or it can be generated on site by a iogas CHP or natural gas CHP or other renewable source (ex. PV)&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;In this field should be indicated the source of the electricity used in the process (mixers, feeders, etc). The source can be the nationl grid or it can be generated on site by a iogas CHP or natural gas CHP or other renewable source (ex. PV)&lt;/div&gt;</summary>
		<author><name>Andrea C</name></author>
	</entry>
</feed>